652 West 163rd St, Manhattan
- Built 1923
- 6 floors
- 54 residential units
- Elevator apartment building
En español: 16 violaciones de Clase C abiertas (peligro inmediato) y 47 abiertas en total.
Open violations are sitting, with little movement either way. 16 open Class C, with 0 certifications filed and 1 new Class C in the last 180 days, too few to call a direction.
Since September 28, 2023, certifications were filed on 9 Class C violations, all 9 by the original certify-by date. How certification works
- OATH hearings
- A hearing on a DOB summons is set for November 12, 2026.
- DOB violations
- 1 active DOB violation, issued August 8, 2002.
- DOB complaints
- 3 DOB complaints in the last 12 months. The newest was filed September 4, 2026.
- DOB facade
- Rated Safe in the latest facade report, filed May 7, 2025 (inspection cycle 9).
- Local Law 97
- Covered from 2026 as a rent-regulated building (DOB's list, March 1, 2026).
- Rent stabilization
- Has rent-stabilized apartments (2024 registration).
- HPD emergency repair order
- 1 completed HPD emergency repair order since September 28, 2023: a general construction order, opened November 28, 2023, awarded for $617.
Open violations by class. A party is named only where the building's HPD registration covers the date a violation was filed.
| Filed | Category | Status | Number | Registered party when filed |
|---|---|---|---|---|
| Class C | 16 open most often Lead Paint | |||
| Heat / Hot Water | Notice sent | 19179416 | ACQUISITION AMERICA VIII LLC | |
| Notice sent | 17568228 | |||
| Notice sent | 17568224 | |||
| Notice sent | 17568223 | |||
| Lead Paint | Notice sent | 17023966 | ||
| Vermin / Infestation | Notice sent to tenant | 17005196 | ||
| Lead Paint | Notice sent | 16730800 | ||
| Lead Paint | Notice sent | 16730799 | ||
| Lead Paint | Notice sent | 16730798 | ||
| Lead Paint | Notice sent | 16730797 | ||
| Lead Paint | Defect letter sent | 16610293 | ||
| Lead Paint | Defect letter sent | 16610292 | ||
| Lead Paint | Defect letter sent | 16610290 | ||
| Fire Safety | Not complied with | 16302188 | ||
| Heat / Hot Water | Notice sent | 16302186 | ||
| Heat / Hot Water | Notice sent | 16302185 | ||
| Class B | 29 open most often Fire Safety | |||
| Vermin / Infestation | Notice sent | 17568227 | ||
| Notice sent | 17568226 | |||
| Notice sent | 17568225 | |||
| Fire Safety | Notice sent | 17008064 | ||
| Fire Safety | Notice sent | 17008063 | ||
| Mold | No access to reinspect (first try) | 17308890 | ||
| Notice sent | 17005204 | |||
| Fire Safety | Notice sent | 17005203 | ||
| Fire Safety | Notice sent | 17005202 | ||
| Notice sent | 17005200 | |||
| Notice sent | 17005199 | |||
| Notice sent | 17005198 | |||
| Notice sent | 17005197 | |||
| Fire Safety | Notice sent | 17005195 | ||
| Fire Safety | Notice sent | 17005194 | ||
| Fire Safety | Notice sent | 17005193 | ||
| Fire Safety | Notice sent | 17005192 | ||
| Notice sent | 17005190 | |||
| Notice sent | 16601523 | |||
| Notice sent | 16601522 | |||
| Fire Safety | Notice sent | 16337538 | ||
| Fire Safety | Notice sent | 16337537 | ||
| Notice sent | 16305458 | |||
| Notice sent | 16305457 | |||
| Notice sent | 16302190 | |||
| Notice sent | 16302189 | |||
| Mold | No access to reinspect (first try) | 16302187 | ||
| Fire Safety | Notice sent | 16302184 | ||
| Fire Safety | Notice sent | 16302183 | ||
| OATH/ECB | 2 open | |||
| Construction, Class 2 | Hearing pending | 39203115N | ||
| Elevators, Class 1 | Found in violation | 39142708M | ||