80-09 134th St
Queens, NY 11435
80-09 134th Street is an elevator building with 139 apartments, built in 1949. It has 249 open violations, 62 of them Class C, immediately hazardous. The oldest open HPD violation was filed on January 19, 2023.
En español: 62 violaciones de Clase C abiertas (peligro inmediato) y 249 abiertas en total. La más antigua del HPD lleva 3 años abierta, desde el 19 de enero de 2023.
Open now, most hazardous first
- 62Get these certified
Class C, immediately hazardous, filed in the last 3 years. Most often Vermin / Infestation.
- 186See the 186
Class B, hazardous, filed in the last 3 years. Most often Fire Safety.
- 1See it
OATH/ECB summons still active
4.5 open Class C per 10 apartments. Across the city: 0.7.
Certifications are being filed at least twice as fast as new violations come in. 184 certifications filed against 38 new Class C in the last 180 days.
Since November 27, 2023, certifications were filed on 127 Class C violations: 124 by the original certify-by date, 3 after it. HPD now marks 1 of them False Certification. HPD can grant a postponement, and this count uses the original date. A filing after that date may still have been on time. How certification works
The original certify-by dates on the 248 open HPD violations run from January 26, 2024 to January 6, 2027.
- Zoning district
- R6A
- Lot area
- 55,600 sq ft
- Floor area
- 190,866 sq ft
- Last transfer
- No price recorded
- Last sale
- $87,200,000The same price is recorded on 2 lots on this block that day.
- Tax lot (BBL)
- 4-09663-0002
- Neighborhood
- Jamaica Hills-Briarwood
Open violations by class. A party is named only where the building's HPD registration covers the date a violation was filed.
| Filed | Category | Status | Number | Registered party when filed |
|---|---|---|---|---|
| Class C | 62 open most often Vermin / Infestation | |||
| Notice sent | 19340549 | BRIARWOOD AFFORDABLE LLC | ||
| § 27-2026 ADM CODE Remove all obstructions from water closet ,, in the bathroom | ||||
| Vermin / Infestation | Notice sent to tenant | 19329373 | BRIARWOOD AFFORDABLE LLC | |
| HMC ADM CODE: § 27-2017.4 abate the infestation consisting of mice in the entire apartment | ||||
| Fire Safety | Notice sent | 19328924 | BRIARWOOD AFFORDABLE LLC | |
| § 27-2005, 2007 ADM CODE Remove device preventing door from being self-closing table holding door open at laundry room at cellar, section 'right-wing', at north | ||||
| Heat / Hot Water | Certified on time | 19328923 | BRIARWOOD AFFORDABLE LLC | |
| § 27-2033 ADM CODE Provide ready access to buildings heating system door locked at cellar at boiler room | ||||
| Heat / Hot Water | CIV14 mailed | 19328922 | BRIARWOOD AFFORDABLE LLC | |
| § 27-2031 ADM CODE Provide hot water at all hot water fixtures in the entire apartment | ||||
| CIV14 mailed | 19328921 | BRIARWOOD AFFORDABLE LLC | ||
| § 27-2026 ADM CODE Repair the flushing apparatus and maintain same so as to flush effectively the water closet .. In the bathroom | ||||
| Vermin / Infestation | CIV14 mailed | 19312865 | BRIARWOOD AFFORDABLE LLC | |
| HMC ADM CODE: § 27-2017.4 abate the infestation consisting of roaches in the entire apartment | ||||
| Fire Safety | To be reinspected | 19297158 | ||
| § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) (C) MDL and 28 RCNY §25-171: Replace or repair the self-closing doors that is missing or defective hinges at compactor closet door at public hall, 6th story, section '80-08', at north | ||||
| Vermin / Infestation | Certified on time | 19278256 | ||
| HMC ADM CODE: § 27-2017.4 abate the infestation consisting of roaches at compactor closet, 6th story, section '80-08-L-W', at south | ||||
| Notice sent | 19278247 | |||
| § 27-2026, 2027 HMC: Properly repair the source and abate the evidence of a water leak at ceiling in the bathroom | ||||
| Fire Safety | Certified on time | 19271360 | ||
| § 27-2005 HMC: Properly repair or replace the broken or defective wire mesh glass pane at fire door leading to north yard at basement at public hall, section '80-08' | ||||
| CIV14 mailed | 19270835 | |||
| § 27-2043.1 HMC Install the missing or repair/replace the defective window guard(S) in accordance with the specifications of the new york city health code section 24 RCNY chapter 12. Wg to install = 1, wg to replace = 0, wg to repair = 0 in the entire apartment | ||||
| CIV14 mailed | 19268677 | |||
| § 27-2026 ADM CODE Repair the leaky and/or defective faucets at bathtub in the bathroom | ||||
| Fire Safety | Notice sent | 19265228 | ||
| § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) (C) MDL and 28 RCNY §25-171: Replace or repair the self-closing doors that is missing or defective hinges in the entrance | ||||
| Lead Paint | No access to reinspect (first try) | 19260182 | ||
| § 27-2056.6 ADM CODE - correct the lead-based paint hazard - paint that tested positive for lead content and that is peeling or on a deteriorated subsurface - using work practices set forth in 28 RCNY §11-06(B)(2) north wall in the foyer | ||||
| Vermin / Infestation | CIV14 mailed | 19250849 | ||
| HMC ADM CODE: § 27-2017.4 abate the infestation consisting of roaches in the entire apartment | ||||
| Vermin / Infestation | CIV14 mailed | 19254884 | ||
| HMC ADM CODE: § 27-2017.4 abate the infestation consisting of roaches in the entire apartment | ||||
| Vermin / Infestation | CIV14 mailed | 19254632 | ||
| HMC ADM CODE: § 27-2017.4 abate the infestation consisting of roaches in the entire apartment | ||||
| CIV14 mailed | 19254592 | |||
| § 27-2043.1 HMC Install the missing or repair/replace the defective window guard(S) in accordance with the specifications of the new york city health code section 24 RCNY chapter 12. Wg to install = 0; wg to replace = 0; wg to repair = 2; in the entire apartment | ||||
| Vermin / Infestation | CIV14 mailed | 19254568 | ||
| HMC ADM CODE: § 27-2017.4 abate the infestation consisting of roaches in the entire apartment | ||||
| Vermin / Infestation | CIV14 mailed | 19254543 | ||
| HMC ADM CODE: § 27-2017.4 abate the infestation consisting of roaches in the entire apartment | ||||
| Vermin / Infestation | CIV14 mailed | 19254541 | ||
| HMC ADM CODE: § 27-2017.4 abate the infestation consisting of mice in the entire apartment | ||||
| Vermin / Infestation | CIV14 mailed | 19253886 | ||
| HMC ADM CODE: § 27-2017.4 abate the infestation consisting of mice in the entire apartment | ||||
| Vermin / Infestation | CIV14 mailed | 19253885 | ||
| HMC ADM CODE: § 27-2017.4 abate the infestation consisting of roaches in the entire apartment | ||||
| Fire Safety | No access to reinspect (first try) | 19194264 | ||
| § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) (C) MDL and 28 RCNY §25-171: Replace or repair the self-closing doors that is missing or defective hinges in the entrance | ||||
| Vermin / Infestation | CIV14 mailed | 19194261 | ||
| HMC ADM CODE: § 27-2017.4 abate the infestation consisting of mice in the entire apartment | ||||
| Vermin / Infestation | CIV14 mailed | 19194260 | ||
| HMC ADM CODE: § 27-2017.4 abate the infestation consisting of roaches in the entire apartment | ||||
| Vermin / Infestation | CIV14 mailed | 19182986 | ||
| HMC ADM CODE: § 27-2017.4 abate the infestation consisting of roaches in the entire apartment | ||||
| Vermin / Infestation | CIV14 mailed | 19182985 | ||
| HMC ADM CODE: § 27-2017.4 abate the infestation consisting of mice in the entire apartment | ||||
| CIV14 mailed | 19181710 | |||
| § 27-2043.1 HMC Install the missing or repair/replace the defective window guard(S) in accordance with the specifications of the new york city health code section 24 RCNY chapter 12. Wg to install = 2, wg to replace = 0, wg to repair = 0 in the entire apartment | ||||
| Vermin / Infestation | Notice sent to tenant | 19177433 | ||
| HMC ADM CODE: § 27-2017.4 abate the infestation consisting of roaches in the entire apartment | ||||
| Vermin / Infestation | Notice sent to tenant | 19177428 | ||
| HMC ADM CODE: § 27-2017.4 abate the infestation consisting of roaches in the entire apartment | ||||
| Vermin / Infestation | Notice sent to tenant | 19177403 | ||
| HMC ADM CODE: § 27-2017.4 abate the infestation consisting of mice in the entire apartment | ||||
| Vermin / Infestation | Notice sent to tenant | 19177400 | ||
| HMC ADM CODE: § 27-2017.4 abate the infestation consisting of roaches in the entire apartment | ||||
| Heat / Hot Water | Notice sent | 19107488 | ||
| § 27-2033 ADM CODE Provide ready access to buildings heating system . At boiler room | ||||
| Heat / Hot Water | Notice sent | 19107319 | ||
| § 27-2033 ADM CODE Provide ready access to buildings heating system door is locked at cellar story at boiler room | ||||
| Notice sent | 19094305 | |||
| § 27-2005 HMC: Properly repair or replace the broken or defective broken lock and asamblies at building entrance door at public hall, 1st story | ||||
| Fire Safety | False certification | 19094304 | ||
| § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) (C) MDL and 28 RCNY §25-171: Replace or repair the self-closing doors that is missing or defective latch from vestibule door to public hall door at public hall, 1st story | ||||
| Vermin / Infestation | Not complied with | 18944365 | ||
| HMC ADM CODE: § 27-2017.4 abate the infestation consisting of mice in the entire apartment | ||||
| Vermin / Infestation | Notice sent to tenant | 18827530 | ||
| HMC ADM CODE: § 27-2017.4 abate the infestation consisting of roaches in the entire apartment | ||||
| Fire Safety | Notice sent | 18790217 | ||
| § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) (C) MDL and 28 RCNY §25-171: Replace or repair the self-closing doors that is missing or defective hinges in the foyer | ||||
| Fire Safety | Not complied with | 18726892 | ||
| § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) (C) MDL and 28 RCNY §25-171: Replace or repair the self-closing doors that is missing or defective hinges at door in the entrance | ||||
| Fire Safety | Notice sent | 18667181 | ||
| § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) (C) MDL and 28 RCNY §25-171: Replace or repair the self-closing doors that is missing or defective hinges at door in the entrance | ||||
| Fire Safety | Notice sent | 18655080 | ||
| § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) (C) MDL and 28 RCNY §25-171: Replace or repair the self-closing doors that is missing or defective hinges at door in the entrance | ||||
| Fire Safety | Not complied with | 18491221 | ||
| § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) (C) MDL and 28 RCNY §25-171: Replace or repair the self-closing doors that is missing or defective latch vestibule to public hall , 1st story | ||||
| Fire Safety | Not complied with | 18491220 | ||
| § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) (C) MDL and 28 RCNY §25-171: Replace or repair the self-closing doors that is missing or defective hinges hopper inside compactor closet at public hall, 5th story, section '5F-5Q', at north | ||||
| Not complied with | 18470281 | |||
| § 27-2005 HMC: Properly repair or replace the broken or defective lock assembly at 2nd vestibule door from north at vestibule. At basment story | ||||
| Vermin / Infestation | CIV14 mailed | 17910394 | ||
| HMC ADM CODE: § 27-2017.4 abate the infestation consisting of roaches in the entire apartment | ||||
| Vermin / Infestation | CIV14 mailed | 17910393 | ||
| HMC ADM CODE: § 27-2017.4 abate the infestation consisting of mice in the entire apartment | ||||
| Lead Paint | Notice sent | 17835191 | ||
| § 27-2056.7, 27-2056.8, 27-2056.9 ADM CODE - certify compliance with lead-based paint hazard control requirements during period of unit vacancy by performing activities necessary to abate presumed lead paint that is xrf tested inconclusive at 0.5 MG/CM2 (28 RCNY §11-07(B)) from required window and/or door friction surfaces and make floors smooth and cleanable, in an apartment with a child under six | ||||
| Lead Paint | Notice sent | 17834123 | ||
| § 27-2056.6 ADM CODE - correct the lead-based paint hazard-paint that is xrf tested inconclusive for lead content at 0.5MG/CM2 and is presumed lead paint as set forth in (28 RCNY §11-07(B)) and that is peeling or on a deteriorated subsurface-using work practices set forth in 28 RCNY §11-06(B)(2) 1st door from east at south wall, 1st door frame from east at south wall in the foyer | ||||
| Notice sent | 17818166 | |||
| § 27-2043.1 HMC Install the missing or repair/replace the defective window guard(S) in accordance with the specifications of the new york city health code section 24 RCNY chapter 12. Wg to install = 0; wg to replace = 0; wg to repair = 6; in the entire apartment | ||||
| Notice sent | 17704963 | |||
| § 27-2070 ADM CODE Provide an adequate supply of gas to the fixtures at range in the kitchen | ||||
| Lead Paint | Notice sent | 17604882 | ||
| § 27-2056.6 ADM CODE - correct the lead-based paint hazard-paint that is xrf tested inconclusive for lead content at 0.5MG/CM2 and is presumed lead paint as set forth in (28 RCNY §11-07(B)) and that is peeling or on a deteriorated subsurface-using work practices set forth in 28 RCNY §11-06(B)(2) 1st door from north at east wall in the foyer | ||||
| Fire Safety | Notice sent | 17604866 | ||
| § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) (C) MDL and 28 RCNY §25-171: Replace or repair the self-closing doors that is missing or defective defective hinges in the entrance | ||||
| Fire Safety | Notice sent | 17597652 | ||
| § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) (C) MDL and 28 RCNY §25-171: Replace or repair the self-closing doors that is missing or defective hinges in the entrance | ||||
| Vermin / Infestation | No access to reinspect (first try) | 17384880 | ||
| HMC ADM CODE: § 27-2017.4 abate the infestation consisting of roaches in the entire apartment | ||||
| Lead Paint | Notice sent | 17180431 | ||
| § 27-2056.7, 27-2056.8, 27-2056.9 ADM CODE -certify compliance with lead-based paint hazard control requirements during period of unit vacancy by performing activities necessary to abate tested lead-based paint from required window and/or door friction surfaces for apartment and make floors smooth and cleanable, positive lead-based paint in an apartment with a child under six | ||||
| Lead Paint | Notice sent | 16764309 | ||
| § 27-2056.7, 27-2056.8, 27-2056.9 ADM CODE - certify compliance with lead-based paint hazard control requirements during period of unit vacancy by performing activities necessary to abate presumed lead paint that is xrf tested inconclusive at 0.5 MG/CM2 (28 RCNY §11-07(B)) from required window and/or door friction surfaces and make floors smooth and cleanable, in an apartment with a child under six | ||||
| Fire Safety | Not complied with | 16757748 | ||
| § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) (C) MDL and 28 RCNY §25-171: Replace or repair the self-closing doors that is missing or defective hinge in the entrance | ||||
| Fire Safety | No access to reinspect (first try) | 16757685 | ||
| § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) (C) MDL and 28 RCNY §25-171: Replace or repair the self-closing doors that is missing or defective hinge in the entrance | ||||
| Vermin / Infestation | Not complied with | 16540725 | ||
| HMC ADM CODE: § 27-2017.4 abate the infestation consisting of roaches in the entire apartment | ||||
| In HPD's words. Apartment numbers are left out. | ||||
| Class B | 186 open most often Fire Safety | |||
| Notice sent | 19398818 | BRIARWOOD AFFORDABLE LLC | ||
| Notice sent | 19398817 | BRIARWOOD AFFORDABLE LLC | ||
| Notice sent | 19398816 | BRIARWOOD AFFORDABLE LLC | ||
| Notice sent | 19340551 | BRIARWOOD AFFORDABLE LLC | ||
| Notice sent | 19340550 | BRIARWOOD AFFORDABLE LLC | ||
| Notice sent | 19337415 | BRIARWOOD AFFORDABLE LLC | ||
| Notice sent | 19329375 | BRIARWOOD AFFORDABLE LLC | ||
| Notice sent | 19329374 | BRIARWOOD AFFORDABLE LLC | ||
| Notice sent | 19329372 | BRIARWOOD AFFORDABLE LLC | ||
| Notice sent | 19329371 | BRIARWOOD AFFORDABLE LLC | ||
| Fire Safety | Notice sent | 19328920 | BRIARWOOD AFFORDABLE LLC | |
| Fire Safety | Notice sent | 19328919 | BRIARWOOD AFFORDABLE LLC | |
| Notice sent | 19318023 | BRIARWOOD AFFORDABLE LLC | ||
| Notice sent | 19312864 | BRIARWOOD AFFORDABLE LLC | ||
| Notice sent | 19312862 | BRIARWOOD AFFORDABLE LLC | ||
| Notice sent | 19312861 | BRIARWOOD AFFORDABLE LLC | ||
| Notice sent | 19300660 | BRIARWOOD AFFORDABLE LLC | ||
| Notice sent | 19297159 | |||
| Notice sent | 19297157 | |||
| Notice sent | 19297155 | |||
| Notice sent | 19297154 | |||
| Certified on time | 19278254 | |||
| Certified on time | 19278253 | |||
| Fire Safety | Certified on time | 19278252 | ||
| Fire Safety | Certified on time | 19278251 | ||
| Certified on time | 19278250 | |||
| Notice sent | 19278249 | |||
| Notice sent | 19278248 | |||
| CIV14 mailed | 19271359 | |||
| Fire Safety | CIV14 mailed | 19271355 | ||
| Fire Safety | CIV14 mailed | 19271354 | ||
| CIV14 mailed | 19271353 | |||
| Certified on time | 19281340 | |||
| Certified on time | 19268678 | |||
| CIV14 mailed | 19268676 | |||
| CIV14 mailed | 19268675 | |||
| Certified on time | 19265230 | |||
| Certified on time | 19265229 | |||
| CIV14 mailed | 19265227 | |||
| CIV14 mailed | 19265226 | |||
| CIV14 mailed | 19265225 | |||
| CIV14 mailed | 19265224 | |||
| CIV14 mailed | 19265223 | |||
| CIV14 mailed | 19265222 | |||
| CIV14 mailed | 19265221 | |||
| CIV14 mailed | 19265220 | |||
| CIV14 mailed | 19265219 | |||
| CIV14 mailed | 19265218 | |||
| CIV14 mailed | 19254887 | |||
| CIV14 mailed | 19254882 | |||
| CIV14 mailed | 19254877 | |||
| CIV14 mailed | 19254875 | |||
| CIV14 mailed | 19254870 | |||
| CIV14 mailed | 19254761 | |||
| CIV14 mailed | 19254722 | |||
| CIV14 mailed | 19254710 | |||
| CIV14 mailed | 19254704 | |||
| CIV14 mailed | 19254694 | |||
| CIV14 mailed | 19254679 | |||
| CIV14 mailed | 19254651 | |||
| CIV14 mailed | 19254627 | |||
| CIV14 mailed | 19254625 | |||
| CIV14 mailed | 19254619 | |||
| CIV14 mailed | 19254614 | |||
| CIV14 mailed | 19254603 | |||
| CIV14 mailed | 19254598 | |||
| CIV14 mailed | 19254566 | |||
| CIV14 mailed | 19254537 | |||
| CIV14 mailed | 19254534 | |||
| CIV14 mailed | 19254530 | |||
| CIV14 mailed | 19254528 | |||
| CIV14 mailed | 19254506 | |||
| CIV14 mailed | 19254478 | |||
| CIV14 mailed | 19254407 | |||
| CIV14 mailed | 19254381 | |||
| CIV14 mailed | 19254358 | |||
| CIV14 mailed | 19254357 | |||
| Fire Safety | CIV14 mailed | 19253976 | ||
| Fire Safety | CIV14 mailed | 19253972 | ||
| CIV14 mailed | 19253967 | |||
| CIV14 mailed | 19253957 | |||
| CIV14 mailed | 19253948 | |||
| CIV14 mailed | 19253881 | |||
| CIV14 mailed | 19253848 | |||
| CIV14 mailed | 19253843 | |||
| CIV14 mailed | 19253841 | |||
| Certified on time | 19220964 | |||
| Certified on time | 19220961 | |||
| Notice sent | 19194265 | |||
| Mold | Notice sent to tenant | 19183004 | ||
| Fire Safety | Notice sent | 19183003 | ||
| Fire Safety | Notice sent | 19183002 | ||
| Notice sent | 19183000 | |||
| Notice sent | 19182997 | |||
| Notice sent | 19182996 | |||
| Notice sent | 19182995 | |||
| Notice sent | 19182993 | |||
| Notice sent | 19182991 | |||
| Notice sent | 19182990 | |||
| Fire Safety | Notice sent | 19182988 | ||
| Fire Safety | Notice sent | 19182987 | ||
| Notice sent | 19182981 | |||
| Notice sent | 19182980 | |||
| Notice sent | 19181711 | |||
| Fire Safety | Notice sent | 19177431 | ||
| Fire Safety | Notice sent | 19177430 | ||
| Notice sent | 19177429 | |||
| Notice sent | 19177427 | |||
| Notice sent | 19177426 | |||
| Notice sent | 19177425 | |||
| Notice sent | 19177424 | |||
| Notice sent | 19177423 | |||
| Notice sent | 19177422 | |||
| Notice sent | 19177421 | |||
| Notice sent | 19177420 | |||
| Notice sent | 19177419 | |||
| Fire Safety | Notice sent | 19177418 | ||
| Fire Safety | Notice sent | 19177417 | ||
| Notice sent | 19177415 | |||
| Notice sent | 19177414 | |||
| Notice sent | 19177412 | |||
| Notice sent | 19177411 | |||
| Notice sent | 19177410 | |||
| Notice sent | 19177409 | |||
| Fire Safety | Notice sent | 19177408 | ||
| Fire Safety | Notice sent | 19177407 | ||
| Notice sent | 19177405 | |||
| Notice sent | 19177404 | |||
| Fire Safety | Notice sent | 19177402 | ||
| Fire Safety | Notice sent | 19177401 | ||
| Fire Safety | Notice sent | 19177399 | ||
| Notice sent | 19177398 | |||
| Notice sent | 19177397 | |||
| Notice sent | 19177396 | |||
| Notice sent | 19177395 | |||
| Notice sent | 19177394 | |||
| Fire Safety | Notice sent | 19177393 | ||
| Fire Safety | Notice sent | 19177392 | ||
| Notice sent | 19177391 | |||
| Notice sent | 19177389 | |||
| Notice sent | 19177388 | |||
| Fire Safety | Notice sent | 19177387 | ||
| Fire Safety | Notice sent | 19177386 | ||
| Notice sent | 19177383 | |||
| Notice sent | 19177382 | |||
| Notice sent | 19177380 | |||
| Notice sent | 19177378 | |||
| Notice sent | 19177377 | |||
| Notice sent | 19177376 | |||
| Notice sent | 19180412 | |||
| Notice sent | 19180411 | |||
| Notice sent | 19180410 | |||
| Notice sent | 19180407 | |||
| Notice sent | 19180406 | |||
| Notice sent | 19180403 | |||
| Notice sent | 19180402 | |||
| Fire Safety | CIV14 mailed | 19167575 | ||
| Fire Safety | CIV14 mailed | 19167574 | ||
| CIV14 mailed | 19167566 | |||
| Notice sent | 19167564 | |||
| CIV14 mailed | 19107485 | |||
| CIV14 mailed | 19107316 | |||
| Fire Safety | CIV14 mailed | 19113106 | ||
| Fire Safety | CIV14 mailed | 19113102 | ||
| Notice sent | 19039208 | |||
| Notice sent | 19039207 | |||
| Notice sent | 18991174 | |||
| Mold | Notice sent to tenant | 19281671 | ||
| Not complied with | 18980916 | |||
| Not complied with | 18980914 | |||
| Not complied with | 18980912 | |||
| Not complied with | 18945726 | |||
| Fire Safety | Not complied with | 18944367 | ||
| Fire Safety | Not complied with | 18944366 | ||
| Mold | Notice sent to tenant | 19180026 | ||
| Mold | Notice sent to tenant | 19180025 | ||
| Fire Safety | Notice sent | 18805397 | ||
| Fire Safety | Notice sent | 18805396 | ||
| Mold | Notice sent to tenant | 19040719 | ||
| Mold | Notice sent to tenant | 19040718 | ||
| Fire Safety | Notice sent | 18655079 | ||
| Fire Safety | Notice sent | 18655078 | ||
| Invalid certification | 18597607 | |||
| Notice sent | 18573102 | |||
| Notice sent | 17833735 | |||
| Not complied with | 17497700 | |||
| OATH/ECB | 1 open | |||
| Local Law, Class 2 | Found in violation | 37034824Z | ||
Is this your building?Also for tenants and buyers
HPD takes complaints from tenants through 311.
JustFix mails your landlord a free letter asking for repairs, by USPS Certified Mail. Start the letter on JustFix
For a housing court case, the report puts every open violation here on one record you can forward, each with the date on its notice. See what's in it
HPD and other city records
- Open Class C, week by week
- 49 on September 24, 2026 and 62 on November 15, with a high of 64 on October 8.
- HPD, by year
- From 2018 to 2026, HPD filed 685 violations and closed 360, all classes.
Year Filed Closed 2026 430 162 2025 84 82 2024 111 84 2023 40 24 2022 14 6 2021 5 2 2018 1 0 - Energy benchmarking
- ENERGY STAR score 46 for 2025, against a median of 69 for Multifamily Housing that year.
- Local Law 97
- Covered under Article 321, the path for certain affordable housing and houses of worship (DOB's list, March 1, 2026). Being on the list does not mean the building fails the law or owes a penalty.
- Bedbug report
- Filed December 8, 2025, for the year to October 31, 2025. Buildings with 3 or more apartments file one with HPD every year. The report is filed whether or not the building had bedbugs.
- Tax exemption
- Has an Article XI tax exemption (DOF 2026/27 roll).
- HPD emergency repair orders
- 3 completed HPD emergency repair orders since November 27, 2023, awarded for $4,487 in total. The most recent of the 3, a general construction order, was opened July 30, 2026. The amount is what HPD awarded for the work, not a bill. What was charged or paid is not shown here.
Hearings and penalties
- OATH/ECB summonses
- 27 DOB and FDNY summonses here since January 1, 2019, with $49,247 in penalties imposed. 1 of them is still active, the one listed under OATH/ECB. 7 judgments docketed, the latest on September 30, 2026. A docketed judgment shows up in a title search.
- October 22, 2026, FDNY: Rooftop access and means of egress.
- October 22, 2026, FDNY: Labels markings.
- February 9, 2026, FDNY: Fire protection systems: Fail to prevent unnecessary unwarranted alarms. In violation, $750 penalty imposed.
The newest 3 of 27 summonses OATH lists here.
- Housing court
- 3 open housing court cases. The newest opened August 14, 2026. 8 housing court cases here since 2008, most of them tenant actions. These are HPD's cases to get repairs made or to get in to inspect, and tenants' repair cases HPD joined. Evictions are not counted.
DOB records
- DOB violations
- 2 active DOB violations. The newest was issued February 22, 2024.
- DOB complaints
- 9 DOB complaints in the last 12 months. The newest was filed October 19, 2026. A complaint is only a report to DOB. DOB inspects and decides whether there is a violation.
- DOB, all years
- 88 DOB complaints from 1991 through November 25, 2026. 88 DOB violations since 1988, 70 resolved and 16 dismissed in DOB's records.
- DOB facade
- No Report Filed for inspection cycle 9. Reports in earlier inspection cycles rated it Unsafe in 2007, and Safe with a repair and maintenance program (SWARMP) in 2008, 2013 and 2018.
- DOB permits
- DOB NOW lists 9 work permits here, the newest issued April 11, 2024, for Mechanical Systems work.
- Mechanical Systems, issued April 11, 2024, expired November 7, 2024.
- Plumbing, issued April 3, 2024, signed off.
- Antenna, issued March 22, 2023, signed off.
The newest 3 of 9 permits DOB NOW lists here.
- Certificate of occupancy
- DOB issued a final certificate of occupancy on January 12, 2023.
- Boiler inspection
- 7 boilers, all inspected in 2025, the latest on December 23. Boilers in buildings with 6 or more apartments are inspected every calendar year.
The building report
- The city's wording on the 187 other open violations this page lists without it.
- What each of the 10 city statuses here means, and how many of these carry it.
- How it compares with the 679 Queens buildings with 100 to 199 apartments.
- All 9 DOB NOW work permits, with job numbers and each job's estimated cost.
- All 27 DOB and FDNY summonses at OATH/ECB, with each outcome, the penalty imposed and any docketing date, and the hearing date on the 1 still active.
- Every other record on this page, on a cover you can forward.


Get the report, $19 See a sample report
You get it on your order page and by email. If it tells you nothing you did not already know, reply and we refund it.